Automated Equipment Platform

Single-Channel Electroporator

The Single-Channel Electroporator is a state-of-the-art electroporation system designed for efficient delivery of RNP (Ribonucleoprotein) complexes and other nucleic acids into mammalian cells. This system enables precise control of electrical parameters, ensuring high transfection efficiency while maintaining excellent cell viability. Ideal for gene editing projects requiring consistent and reproducible results.

Product Code: LMAE-01

Market Price:¥150,000

Product Overview

Advanced electroporation system designed for precise RNP delivery and electrotransfection processes in gene editing workflows

Applications

  • RNP Delivery: Efficient delivery of ribonucleoprotein complexes for CRISPR gene editing
  • Precision Control: Programmable voltage, pulse duration, and pulse number for optimal transfection efficiency
  • Cell Type Versatility: Compatible with various cell types including primary cells, stem cells, and cell lines
  • Automated Workflow: Integrated with liquid handling systems for seamless automation
  • Compact Design: Space-saving design suitable for standard laboratory benchtops

Technical Specifications

Dimensions450mm (W) × 500mm (D) × 350mm (H)
Plate Compatibility96-well electroporation plates
Power SupplyAC 100-240V, 50/60Hz
Pulse Duration0.1-99ms, programmable
Pulse Number1-99 pulses per sample
Sample Volume10-200μL per well
Temperature Control4-37°C chamber temperature
ThroughputSingle-channel processing
Voltage Range10-3000V, adjustable in 1V increments
Request a Quote
Fill in your requirements and we will contact you soon

Customer Success Stories

Real-world applications and results from our customers using Single-Channel Electroporator

CAR-T Cell Engineering for Cancer Immunotherapy

Leading Cell Therapy BiotechBiotech Company
Cell TherapyCAR-TCRISPRRNP DeliveryCell Therapy

Challenge

Traditional viral transduction methods for CAR-T manufacturing faced high costs, lengthy production cycles, and regulatory complexity. The company needed a non-viral approach to deliver CRISPR RNP complexes for precise TCR knockout while maintaining high cell viability.

Solution

Implemented the Single-Channel Electroporator for RNP-based gene editing in primary T cells. Optimized electroporation parameters (voltage, pulse duration, pulse number) to achieve efficient CRISPR delivery while preserving T cell functionality and proliferation capacity.

Key Results

85%
Editing Efficiency
+30% vs. previous method
92%
Cell Viability
+15% vs. viral transduction
7 days
Production Time
50% reduction
60%
Cost Reduction
vs. viral vectors

The Single-Channel Electroporator transformed our CAR-T manufacturing process. We achieved reproducible high editing efficiency with excellent cell viability, significantly reducing both time and cost compared to viral methods.

Timeline: 3 months (optimization + validation)

Disease Modeling with Gene-Edited iPSCs

Top-tier Research InstituteResearch Institute
Basic ResearchiPSCDisease ModelingCRISPRStem Cells

Challenge

Creating isogenic iPSC lines with precise gene modifications for disease modeling required high editing efficiency while maintaining pluripotency. Conventional electroporation systems caused significant cell death and loss of stem cell characteristics.

Solution

Utilized the Single-Channel Electroporator's precise control capabilities to deliver Cas9 RNP complexes into iPSCs. Fine-tuned electrical parameters to balance transfection efficiency with cell viability, followed by single-cell cloning to establish edited lines.

Key Results

78%
Editing Success Rate
+25% vs. standard protocols
95%
Pluripotency Retention
Maintained OCT4/NANOG expression
65%
Clone Recovery
+20% vs. previous system
<2%
Off-target Rate
Verified by whole-genome sequencing

This electroporator enabled us to generate multiple isogenic iPSC lines with disease-relevant mutations in just 6 weeks. The high cell viability and preserved pluripotency were critical for our downstream differentiation experiments.

Timeline: 6 weeks (per line)

Related Products

Automated Equipment Platform
Automated Single-Cell Cloning Microscopy System
The Automated Single-Cell Cloning Microscopy System combines advanced imaging technology with intelligent software to streamline the single-cell cloning process. This system automatically identifies, images, and tracks individual cells in multi-well plates, providing documented proof of monoclonality. With high-resolution imaging and AI-powered cell detection, it significantly reduces the time and labor required for establishing verified monoclonal cell lines.

LMAE-02

Automated Equipment Platform
Automated Liquid Handling Workstation
The Automated Liquid Handling Workstation is a versatile robotic platform designed for high-throughput cell editing applications using lipofection transfection methods. This system automates complex liquid handling tasks including reagent dispensing, plate replication, serial dilutions, and transfection mix preparation. With exceptional precision and reproducibility, it eliminates manual pipetting errors and dramatically increases throughput for large-scale gene editing projects.

LMAE-03

ELEM Biotech - 粒曼生物

Professional high-throughput gene editing solutions provider, dedicated to advancing drug discovery and fundamental research innovation.

Contact

Follow Us

© 2026 ELEM Biotech. All rights reserved.